Configure your generator and see the price straight away
Choose the power you need, the engine brand, canopy, fuel tank, starting and extras. The configurator only shows engines that match your power and calculates the price as you go.
Choose the power
Pick the standby rating (ESP) in kVA – the matching prime rating (PRP) is shown next to it. Drag the slider, tap a common size, or let us calculate it from your equipment.
Standby (ESP): for backup when the grid fails, max. 200 hours a year. Prime (PRP): for everyday use with unlimited hours. Prime can differ slightly by engine brand.
110 kVA standby
Power that fits
10 to 2,500 kVA standby with the prime rating shown next to it, and only engine brands with a model close to your size.
Price at every step
Net prices ex works Poland. Standard generators have a fixed list price; extras are shown as an estimate.
Delivery in about 4 weeks
Generators are built in our Polish factory. The typical lead time is about four weeks from order.
Binding offer from our engineers
Send your configuration with one click. Our team checks it and sends you a binding offer.
Configurator
How the configurator works
Six short steps take you from your power requirement to a complete generator with price, documents and drawings.
- 01
Use and power
Tell us whether the generator is for backup, prime or continuous power, then pick the size in kVA or let the calculator work it out from your loads.
- 02
Engine brand
ElectroQuell, Perkins, FPT Iveco, Hyundai or Scania. Only brands with a model close to your size are shown.
- 03
Enclosure
Soundproof or super-silent canopy, open skid for plant rooms, ISO container or road trailer.
- 04
Fuel tank
Standard, 24-hour or 48-hour base tank, or an external tank with automatic refuelling.
- 05
Starting and extras
Manual or automatic start with a transfer switch (ATS), paralleling and optional extras such as remote monitoring.
- 06
Summary and offer
Check your generator, download the documents and request a binding offer with one click.
Configurator
Tips for choosing the right generator
A few things our engineers check on every request. Keep them in mind and your configuration will be close to the final offer.
- Standby or prime power
- Standby (ESP) is for backup when the grid fails, up to 200 hours a year. If the generator runs every day, size it on the prime rating (PRP).
- Plan for motor starting
- Pumps, compressors and lifts draw several times their rated current when they start. Use "Help me calculate" and enter your largest motor and how it starts.
- Leave some reserve
- Diesel generators run best at 50–80 % load. Add 10–25 % for future equipment, and tell the calculator if the site is high up or very hot.
- Think about noise
- Near homes, hospitals or offices choose the super-silent canopy: 62–65 dB(A) at 7 m instead of 70–75 dB(A), roughly half as loud to the ear.
- Runtime and tank rules
- Choose a 24- or 48-hour tank for long outages. In Germany a double-wall tank with leak detection is recommended (AwSV).
- Stage V for mobile units
- Mobile generators sold in the EU need a Stage V engine. If you choose the road trailer, add the Stage V aftertreatment (DPF + SCR).
Configurator
What you get at the end
The summary step gives you everything you need to compare offers, plan the site or prepare a tender.
Price and delivery time
Net price in EUR ex works Poland, with every extra listed, and the expected delivery time.
Spec sheet (PDF)
Ratings, engine, fuel consumption, dimensions, weight and sound level of your exact unit.
Tender specification
A ready-made technical text for tenders and planners, plus the bill of materials.
Drawings
Side view, footprint with clearances and a wiring diagram, ready to download.
About Us
Built in our own factory in Poland
ElectroQuell designs and builds diesel generators from 10 to 2,500 kVA. Every unit in the configurator is a standard model from our range, so the price you see is based on real list prices, not guesses.
Learn more- European production
- Assembled and tested in our Polish factory, delivered in about four weeks after order.
- Proven components
- ElectroQuell alternator and ComAp controller on every unit, with your choice of engine brand.
- Warranty
- 12 months or 1,000 operating hours, whichever comes first.
- Standards
- Ratings to ISO 8528-1. Factory load test with report available as an option.
FAQ
Questions about the configurator
Is the price in the configurator binding?
Standard generators have a fixed list price. Extras are shown as an estimate. When you send your configuration, our engineers check it and send you a binding offer with the final price and delivery date.
Are the prices including VAT and transport?
No. All prices are net in EUR, excluding VAT, ex works Poland. Delivery, installation and commissioning are included only if you select them as an extra.
I do not know how much power I need. What should I do?
Choose "Help me calculate" in the first step. Enter the total load of your equipment, your largest motor and how it starts, and the configurator recommends a size. You can also contact us and our engineers will size it for you.
Can I save or share my configuration?
Yes. As soon as you choose an engine, the page address contains a code for your configuration (#EQ-…). Bookmark it or send the link to a colleague, and the configurator opens with the same choices.
What if I need more than 2,500 kVA or several units?
In the starting step you can choose several units running in parallel, as an island system or in parallel with the grid. For very large or special projects, contact our team.
How long does delivery take?
The typical lead time is about four weeks after order confirmation. The exact date is stated in your binding offer.
Does the configurator only cover diesel generators?
Yes, it covers our diesel range. For gas generators, CHP or other special solutions, please contact us directly.
Configurator
Related solutions
Parallel systems
Several generators working together for more power and N+1 redundancy.
Learn moreMobile units
Trailer-mounted generators for construction sites, events and rental.
Learn moreStage V generators
Low-emission generators with DPF and SCR for EU Stage V compliance.
Learn moreInstallation services
Foundations, electrical connection and commissioning on your site.
Learn more
Not sure which configuration is right?
Send us your requirements or a draft configuration. Our engineers check the sizing, suggest options and prepare a binding offer.
Get in touch
We're here to help and answer any questions you might have. We look forward to hearing from you.
