Hermetically sealed oil transformers and cast-resin dry transformers from 25 to 2500 kVA, for 6.3, 10 and 21 kV networks. Every configuration meets the Ecodesign Tier 2 loss limits.
25–2500 kVA
14 oil and 11 dry ratings
6.3 / 10 / 21 kV
High voltage
420 V or 800 V
Low voltage, 800 V for PV and battery storage
Ecodesign Tier 2
Regulation (EU) No 548/2014
60 months
Warranty from delivery
117
Standard configurations
Why ElectroQuell Energy
Low losses, published in full
Every PNACHO transformer meets the Tier 2 limits of Commission Regulation (EU) No 548/2014 as amended by (EU) 2019/1783. Maximum no-load and load losses are listed for each configuration, so you can compare running costs before you buy.
Tested and documented, unit by unit
Each transformer passes routine tests to IEC 60076 before it ships. It comes with its own test report, the EU declaration of conformity, the rating plate and the operating manual.
One supplier for the whole power supply
ElectroQuell also supplies diesel generator sets built in EU factories. With PNACHO transformers you get the medium-voltage transformer and the backup power from one supplier. Technical support is available in English, German and Polish.
PNACHO-O oil transformers 25–2500 kVA
The PNACHO-O is a three-phase, hermetically sealed oil-immersed distribution transformer. Its corrugated-wall tank has no conservator, so the oil is sealed off from the air, and the transformer can stand indoors or outdoors. It's the usual choice for compact substations, distribution networks, industrial sites and solar parks.
63 models
Popular ratings
Technical data
- Ratings
- 25, 40, 63, 100, 160, 250, 400, 630, 800, 1000, 1250, 1600, 2000 and 2500 kVA
- Voltages
- High voltage 6.3, 10 or 21 kV; low voltage 420 V; an 800 V PV version from 630 kVA up
- Vector group
- Dyn11 (Yzn11 for 25 and 40 kVA); Dyn5 or Yzn5 on request
- Tapping
- Off-circuit, ±3 × 2.5 % (±2 × 2.5 % for 25 and 40 kVA)
- Short-circuit impedance
- 4 % up to 630 kVA, 6 % from 800 kVA
- Cooling and oil
- ONAN, mineral oil to IEC 60296; ester liquid MIDEL 7131 on request
- Windings
- Aluminium; copper on request
- Finish
- RAL 7033, corrosivity class C3
PNACHO-D dry transformers 100–2500 kVA
The PNACHO-D is a three-phase cast-resin dry-type transformer with vacuum-cast epoxy windings. It holds no oil, so it needs no oil sump, and it's built for indoor installation where fire safety matters: in buildings, industrial halls and station rooms. To IEC/EN 60076-11 it is fire class F1 (self-extinguishing), climatic class C3 and environmental class E3.
54 models
Popular ratings
Technical data
- Ratings
- 100, 160, 250, 400, 630, 800, 1000, 1250, 1600, 2000 and 2500 kVA
- Voltages
- High voltage 6.3, 10 or 21 kV; low voltage 420 V; an 800 V PV version from 630 kVA up
- Vector group
- Dyn11; Dyn5 on request
- Tapping
- Off-circuit links, ±2 × 2.5 %
- Short-circuit impedance
- 6 %
- Insulation
- Class F
- Temperature monitoring
- 3 × PT100 sensors in the LV windings and a T-154 monitoring relay
- Partial discharge
- ≤ 10 pC
- Cooling
- AN; forced-air cooling AF (+40 % power) on request
- Protection
- IP00 for indoor use; enclosure IP21–IP44 on request
- Windings
- Aluminium; copper on request
Applications
PV, battery storage, industry, buildings, EV charging and utilities
Solar parks (PV)
From 630 kVA up, both series come with an 800 V low-voltage winding for central PV inverters. Choose the oil version for outdoor stations and the cast-resin version for installation inside a station building.
Battery storage (BESS)
Battery inverters that work at 800 V connect to the same 800 V versions from 630 to 2500 kVA. In hybrid plants this lets you use one transformer type for PV and storage.
Industry
For factories and workshops, both series supply 420 V from 6.3, 10 or 21 kV, from 25 kVA for a small site up to 2500 kVA. The Dyn11 vector group copes well with unbalanced single-phase loads on the low-voltage side.
Buildings
Office blocks, hospitals, shopping centres and car parks usually take a dry transformer indoors. The PNACHO-D has no oil and is fire class F1, so it can sit close to people.
EV charging
A charging hub with several DC fast chargers often needs its own medium-voltage connection. Pick the rating from the chargers' total power and the share that runs at the same time; the FAQ below explains how.
Utilities and grid operators
For distribution networks and compact substations, the hermetically sealed PNACHO-O works indoors or outdoors, at 6.3, 10 or 21 kV.
Standards and documents
PNACHO transformers are designed and tested to:
- IEC/EN 60076 (power transformers), and IEC/EN 60076-11 for the cast-resin series
- EN 50588-1 (medium-power transformers up to 36 kV)
- EN 50708 (additional European requirements for power transformers)
- Commission Regulation (EU) No 548/2014 as amended by (EU) 2019/1783, Ecodesign Tier 2 loss limits
Every transformer comes with:
- the routine test report of that unit
- the EU declaration of conformity
- the rating plate
- the operating manual
On request: dimension drawings and documents for the grid operator. Documents are in English; German on request.
Certifications: CE marking, ISO 9001, ISO 14001
Frequently asked questions
Oil or dry transformer: which do I need?
- Oil (PNACHO-O): for outdoor stations, compact substations and wherever losses count most. At the same rating it has lower no-load losses: 540 W against 990 W at 630 kVA.
- Dry (PNACHO-D): for installation indoors, close to people. It holds no oil, needs no oil sump and is self-extinguishing (fire class F1).
What does Ecodesign Tier 2 mean for a distribution transformer?
Commission Regulation (EU) No 548/2014, as amended by Regulation (EU) 2019/1783, sets maximum no-load and load losses for transformers sold in the EU. Its stricter second stage, Tier 2, has applied since 1 July 2021. Every PNACHO configuration meets the Tier 2 limits, and the maximum loss values are on each product page.
Which voltages do PNACHO transformers come in?
- High voltage: 6.3, 10 or 21 kV.
- Low voltage: 420 V on every rating, or 800 V from 630 kVA up.
- Tapping: off-circuit, ±2 × 2.5 % or ±3 × 2.5 % depending on series and rating.
Other voltages are available on request, for example 400 V or 690 V on the low-voltage side. For other high voltages, ask us.
Do you have transformers for PV and battery storage (800 V)?
Yes. Both series come in an 800 V version from 630 to 2500 kVA, with an 800 V low-voltage winding for central PV and battery inverters.
How do I choose the right kVA rating?
- Add up the apparent power of all loads: kW divided by the power factor.
- Allow for loads that don't run at the same time, and for future growth.
- Choose the next standard rating.
Example: 450 kW at a power factor of 0.9 is 500 kVA, so a 630 kVA transformer leaves room to grow. For PV and battery storage, the rating should at least match the inverters' AC output. The datasheet, available on request, lists the rated currents.
What do no-load and load losses cost over a transformer's life?
No-load losses run 24 hours a day for as long as the transformer is energised. Load losses rise with the square of the load. Take a PNACHO-O 630 kVA:
- 540 W no-load losses × 8,760 h ≈ 4,730 kWh a year.
- At 50 % load for 4,000 hours, its load losses add about 4,600 kWh: a quarter of 4,600 W × 4,000 h.
At an assumed €0.20 per kWh that is about €1,870 a year. Over the many years a transformer runs, lower losses often matter more than a lower purchase price.
Which documents come with each transformer?
- the routine test report of that unit
- the EU declaration of conformity
- the rating plate
- the operating manual
On request we add dimension drawings and documents for the grid operator.
What warranty do you give?
60 months from delivery on every PNACHO transformer.
How is delivery handled within the EU?
All current PNACHO configurations are made to order, with delivery in 16 weeks. We deliver to any EU country. Unloading by crane and placement are available on request. We confirm the delivery date with the quote. Transport is priced in the quote.
Dyn11 or Dyn5: which vector group do I need?
The number gives the phase shift between the high- and low-voltage sides in steps of 30°: 330° for Dyn11 and 150° for Dyn5. Transformers that run in parallel must have the same vector group. So match the group of the existing substation and follow your grid operator's connection rules. PNACHO transformers are Dyn11 as standard (Yzn11 at 25 and 40 kVA); Dyn5 is available on request.
Contact
Request a quote
Tell us:
- the rating (kVA) and quantity
- the high and low voltage
- the vector group
- indoor or outdoor installation
- the delivery address and the date you need it
We reply with the price, the delivery date and the datasheet. Our team answers in English, German and Polish.