PNACHO-O 1600 – 1600 kVA 6.3/0.42 kV Oil-Immersed Distribution Transformer

PNACHO-O

PNACHO-O oil transformer 1600 kVA 6.3/0.42 kV Tier 2

Rated power
1600 kVA
High voltage
6.3 kV
Low voltage
0.42 kV
  • Rated power: 1600 kVA
  • High voltage: 6.3 kV
  • Low voltage: 0.42 kV
  • Vector group: Dyn11
  • No-load losses P0: ≤ 1080 W
  • Load losses Pk (75 °C): ≤ 12000 W
  • Short-circuit impedance uk: 6 %
  • Efficiency class: Tier 2 – (EU) 2019/1783
  • Standards: IEC/EN 60076, EN 50588-1

Warranty: 60 months from delivery.

Certifications: CE marking, ISO 9001, ISO 14001

PNACHO-O 1600 – 1600 kVA 6.3/0.42 kV

The PNACHO-O 1600 is a three-phase, hermetically sealed oil-immersed distribution transformer for 6.3 kV medium-voltage networks. It is engineered to European standards and complies with Ecodesign Tier 2 – Regulation (EU) 2019/1783 – for guaranteed low no-load and load losses over a service life of more than 30 years. The corrugated-wall tank without conservator requires no oil maintenance and is suitable for indoor and outdoor installation.

Technical data

Rated power1600 kVA
High voltage6.3 kV
Low voltage0.42 kV
Vector groupDyn11
Tapping range±3 × 2.5 % (7 positions), off-circuit
Frequency50 Hz
CoolingONAN
No-load losses P0≤ 1080 W
Load losses Pk (75 °C)≤ 12000 W
Short-circuit impedance uk6 %
Insulation level HV (LI/AC)LI 60 / AC 20 kV
Dimensions L × W × H1950 × 1100 × 2050 mm
Total mass≈ 3800 kg
WindingsAluminium (copper on request)
Protection / finishIP00, outdoor, RAL 7033 C3
StandardsIEC/EN 60076, EN 50588-1, EN 50708, (EU) 2019/1783, CE (LVD, EMC, RoHS)
Efficiency classEcodesign Tier 2 – (EU) 2019/1783
Warranty60 months

Standard equipment

  • Hermetically sealed corrugated tank, no conservator
  • Off-circuit tap changer, 7 positions (±3 × 2.5 %)
  • 3 HV porcelain bushings (plug-in EUROMOLD on request), 4 LV bushings with flag terminals
  • Oil level indicator, filling plug, drain valve, thermometer pocket
  • Pressure relief device
  • Bi-directional rollers, 2 lifting lugs, earthing terminals
  • Rating plate and wiring diagram
  • Mineral oil to IEC 60296 (ester MIDEL 7131 on request)
  • Protection relay DGPT2 / DMCR

Testing and conformity

Every unit undergoes routine tests to IEC 60076: no-load loss and current, load loss and impedance at 75 °C, winding resistance, voltage ratio and vector group, induced and applied voltage withstand, insulation resistance, tank tightness test (30 kPa / 12 h). Type tests (lightning impulse, temperature rise, short-circuit withstand, sound level) are available on request. Each transformer is delivered with test report, EU declaration of conformity (CE – LVD, EMC, RoHS, Ecodesign) and operating manual.

Applications

Distribution network operators, industrial plants, commercial buildings, compact substations, renewable energy plants, construction-site and temporary power supply.

Delivery and warranty

Made to order, delivery in 16 weeks; other voltage ratios, vector groups, copper windings and accessories on request. 5-year warranty. Delivery to any EU country, technical support in English, German and Polish.

Optional equipment

  • Copper windings (Cu/Cu)
  • DGPT2 / DMCR protection relay
  • Plug-in EUROMOLD HV bushings 250 A / 24 kV
  • Ester oil MIDEL 7131 (K-class, increased fire safety)
  • Low-voltage 0.4 kV or 0.69 kV
  • Vector group Dyn5 or Yzn5
  • Anti-vibration pads, bird-protection covers
  • On-load tap changer (from 1000 kVA)
  • Enclosure IP23 / IP33